Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 314
Filtrar
1.
J Am Coll Cardiol ; 83(14): 1310-1321, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38569760

RESUMO

BACKGROUND: Transcatheter pulmonary valve replacement (TPVR) with the self-expanding Harmony valve (Medtronic) is an emerging treatment for patients with native or surgically repaired right ventricular outflow tract (RVOT) pulmonary regurgitation (PR). Limited data are available since U.S. Food and Drug Administration approval in 2021. OBJECTIVES: In this study, the authors sought to evaluate the safety and short-term effectiveness of self-expanding TPVR in a real-world experience. METHODS: This was a multicenter registry study of consecutive patients with native RVOT PR who underwent TPVR through April 30, 2022, at 11 U.S. CENTERS: The primary outcome was a composite of hemodynamic dysfunction (PR greater than mild and RVOT mean gradient >30 mm Hg) and RVOT reintervention. RESULTS: A total of 243 patients underwent TPVR at a median age of 31 years (Q1-Q3: 19-45 years). Cardiac diagnoses were tetralogy of Fallot (71%), valvular pulmonary stenosis (21%), and other (8%). Acute technical success was achieved in all but 1 case. Procedural serious adverse events occurred in 4% of cases, with no device embolization or death. Hospital length of stay was 1 day in 86% of patients. Ventricular arrhythmia prompting treatment occurred in 19% of cases. At a median follow-up of 13 months (Q1-Q3: 8-19 months), 98% of patients had acceptable hemodynamic function. Estimated freedom from the composite clinical outcome was 99% at 1 year and 96% at 2 years. Freedom from TPVR-related endocarditis was 98% at 1 year. Five patients died from COVID-19 (n = 1), unknown causes (n = 2), and bloodstream infection (n = 2). CONCLUSIONS: In this large multicenter real-world experience, short-term clinical and hemodynamic outcomes of self-expanding TPVR therapy were excellent. Ongoing follow-up of this cohort will provide important insights into long-term outcomes.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Humanos , Adulto , Valva Pulmonar/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Cateterismo Cardíaco/efeitos adversos , Resultado do Tratamento , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/etiologia , Sistema de Registros , Desenho de Prótese , Estudos Retrospectivos
2.
Circ Cardiovasc Interv ; : e013889, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38606564

RESUMO

BACKGROUND: Anatomic selection for Harmony valve implant is determined with the aid of a screening report and perimeter plot (PP) that depicts the perimeter-derived radius along the right ventricular outflow tract (RVOT) and projects device oversizing. The PP provides an estimation of suitability for implant, but its sensitivity as a screening method is unknown. This study was performed to describe anatomic features and outcomes in patients who underwent Harmony TPV25 implant despite a PP that predicted inadequate oversizing. METHODS: We reviewed RVOT anatomic features and measurements in patients who underwent transcatheter pulmonary valve replacement with the Harmony TPV25 device despite a PP that predicted inadequate oversizing. RESULTS: This study included 22 patients. There were no unsuccessful implants or adverse valve-related events. Anatomic features varied, but all patients fit into 1 of 3 anatomic types characterized by differences in RVOT dimensions. Type 1 patients (n=9) had a long RVOT with a choke point and a wide main pulmonary artery. Type 2 patients (n=6) had a short RVOT that was pyramidal in shape, with no choke point, and extensive main pulmonary artery lengthening/expansion during systole. Type 3 patients (n=7) had a short, bulbous main pulmonary artery with a choke point and an open pulmonary artery bifurcation. CONCLUSIONS: Transcatheter pulmonary valve replacement with the Harmony valve is feasible in some patients whose PP fit analysis predicts inadequate oversizing. All cases in this series fit into 1 of 3 anatomic patterns, which are not identified in the screening report. Implanters must review cases individually to assess the feasibility of the implant.

4.
Theranostics ; 14(4): 1602-1614, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38389840

RESUMO

Background: Markers of aging hold promise in the context of colorectal cancer (CRC) care. Utilizing high-resolution metabolomic profiling, we can unveil distinctive age-related patterns that have the potential to predict early CRC development. Our study aims to unearth a panel of aging markers and delve into the metabolomic alterations associated with aging and CRC. Methods: We assembled a serum cohort comprising 5,649 individuals, consisting of 3,002 healthy volunteers, 715 patients diagnosed with colorectal advanced precancerous lesions (APL), and 1,932 CRC patients, to perform a comprehensive metabolomic analysis. Results: We successfully identified unique age-associated patterns across 42 metabolic pathways. Moreover, we established a metabolic aging clock, comprising 9 key metabolites, using an elastic net regularized regression model that accurately estimates chronological age. Notably, we observed significant chronological disparities among the healthy population, APL patients, and CRC patients. By combining the analysis of circulative carcinoembryonic antigen levels with the categorization of individuals into the "hypo" metabolic aging subgroup, our blood test demonstrates the ability to detect APL and CRC with positive predictive values of 68.4% (64.3%, 72.2%) and 21.4% (17.8%, 25.9%), respectively. Conclusions: This innovative approach utilizing our metabolic aging clock holds significant promise for accurately assessing biological age and enhancing our capacity to detect APL and CRC.


Assuntos
Neoplasias Colorretais , Lesões Pré-Cancerosas , Humanos , Metabolômica , Envelhecimento , Voluntários Saudáveis
5.
Pediatr Cardiol ; 45(4): 795-803, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38360921

RESUMO

This study describes right ventricle (RV) characteristics and right ventricle to pulmonary artery (RV-PA) conduit function pre- and post-repair in patients with tetraology of Fallot with major aortopulmonary collaterals (TOF/MAPCAs). We reviewed patients who underwent single-stage, complete unifocalization, and repair of TOF/MAPCAs between 2006 and 2019 with available pre- and early postoperative echocardiograms. For a subset of patients, 6-12 month follow-up echocardiogram was available. RV and left ventricle (LV) characteristics and RV-PA conduit function were reviewed. Wilcoxon signed rank test and McNemar's test were used. 170 patients were reviewed, 46 had follow-up echocardiograms. Tricuspid valve annular plane systolic excursion (TAPSE) Z-scores were reduced from pre- (Z-score 0.01) to post-repair (Z-score -4.5, p < 0.001), improved but remained abnormal at follow-up (Z-score -4.0, p < 0.001). RV fractional area change (FAC) and LV ejection fraction were not significantly different before and after surgery. Conduit regurgitation was moderate or greater in 11% at discharge, increased to 65% at follow-up. RV-PA conduit failure (severe pulmonary stenosis or severe pulmonary regurgitation) was noted in 61, and 63% had dilated RV (diastolic RV area Z-score > 2) at follow-up. RV dilation correlated with the severe conduit regurgitation (p = 0.018). Longitudinal RV function was reduced after complete repair of TOF/MAPCAs, with decreased TAPSE and preserved FAC and LV ejection fraction. TAPSE improved but did not normalize at follow-up. Severe RV-PA conduit dysfunction was observed prior to discharge in 11% of patients and in 61% at follow-up. RV dilation was common at follow-up, especially in the presence of severe conduit regurgitation.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência Cardíaca , Estenose da Valva Pulmonar , Tetralogia de Fallot , Humanos , Ventrículos do Coração , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/cirurgia , Estudos Retrospectivos , Estenose da Valva Pulmonar/cirurgia , Função Ventricular Direita
6.
Ann Biomed Eng ; 52(5): 1335-1346, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38341399

RESUMO

Blood pressure gradient ( Δ P ) across an aortic coarctation (CoA) is an important measurement to diagnose CoA severity and gauge treatment efficacy. Invasive cardiac catheterization is currently the gold-standard method for measuring blood pressure. The objective of this study was to evaluate the accuracy of Δ P estimates derived non-invasively using patient-specific 0D and 3D deformable wall simulations. Medical imaging and routine clinical measurements were used to create patient-specific models of patients with CoA (N = 17). 0D simulations were performed first and used to tune boundary conditions and initialize 3D simulations. Δ P across the CoA estimated using both 0D and 3D simulations were compared to invasive catheter-based pressure measurements for validation. The 0D simulations were extremely efficient ( ∼ 15 s computation time) compared to 3D simulations ( ∼ 30 h computation time on a cluster). However, the 0D Δ P estimates, unsurprisingly, had larger mean errors when compared to catheterization than 3D estimates (12.1 ± 9.9 mmHg vs 5.3 ± 5.4 mmHg). In particular, the 0D model performance degraded in cases where the CoA was adjacent to a bifurcation. The 0D model classified patients with severe CoA requiring intervention (defined as Δ P ≥ 20 mmHg) with 76% accuracy and 3D simulations improved this to 88%. Overall, a combined approach, using 0D models to efficiently tune and launch 3D models, offers the best combination of speed and accuracy for non-invasive classification of CoA severity.


Assuntos
Coartação Aórtica , Humanos , Coartação Aórtica/diagnóstico por imagem , Pressão Sanguínea , Angiografia por Ressonância Magnética/métodos , Velocidade do Fluxo Sanguíneo , Simulação por Computador
7.
JACC Clin Electrophysiol ; 10(3): 539-550, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38206260

RESUMO

BACKGROUND: Evidence for the efficacy of cardiac resynchronization therapy (CRT) in pediatric and congenital heart disease (CHD) has been limited to surrogate outcomes. OBJECTIVES: This study aimed to assess the impact of CRT upon the risk of transplantation or death in a retrospective, high-risk, controlled cohort at 5 quaternary referral centers. METHODS: Both CRT patients and control patients were <21 years of age or had CHD; had systemic ventricular ejection fraction <45%; symptomatic heart failure; and significant electrical dyssynchrony (QRS duration z score >3 or single-site ventricular pacing >40%) at enrollment. Patients with CRT were matched with control patients via 1:1 propensity score matching. CRT patients were enrolled at CRT implantation; control patients were enrolled at the outpatient clinical encounter where inclusion criteria were first met. The primary endpoint was transplantation or death. RESULTS: In total, 324 control patients and 167 CRT recipients were identified. Mean follow-up was 4.2 ± 3.7 years. Upon propensity score matching, 139 closely matched pairs were identified (20 baseline indices). Of the 139 matched pairs, 52 (37.0%) control patients and 31 (22.0%) CRT recipients reached the primary endpoint. On both unadjusted and multivariable Cox regression analysis, the risk reduction associated with CRT for the primary endpoint was significant (HR: 0.40; 95% CI: 0.25-0.64; P < 0.001; and HR: 0.44; 95% CI: 0.28-0.71; P = 0.001, respectively). On longitudinal assessment, the CRT group had significantly improved systemic ventricular ejection fraction (P < 0.001) and shorter QRS duration (P = 0.015), sustained to 5 years. CONCLUSIONS: In pediatric and CHD patients with symptomatic systolic heart failure and electrical dyssynchrony, CRT was associated with improved heart transplantation-free survival.


Assuntos
Terapia de Ressincronização Cardíaca , Cardiopatias Congênitas , Insuficiência Cardíaca Sistólica , Transplante de Coração , Humanos , Criança , Estudos Retrospectivos , Cardiopatias Congênitas/terapia , Insuficiência Cardíaca Sistólica/terapia
8.
JACC Cardiovasc Interv ; 17(2): 231-244, 2024 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-38267137

RESUMO

BACKGROUND: Transcatheter pulmonary valve replacement (TPVR) has expanded and evolved since its initial commercial approval in the United States in 2010. OBJECTIVES: This study sought to characterize real-world practice, including patient selection, procedural outcomes, complications, and off-label usage. METHODS: Characteristics and outcomes for patients undergoing balloon-expandable TPVR were collected from the American College of Cardiology National Cardiovascular Data Registry IMPACT (Improving Pediatric and Adult Congenital Treatment) Registry. RESULTS: Between April 2016 and March 2021, 4,513 TPVR procedures were performed in patients with a median age of 19 years, 57% with a Melody (Medtronic Inc) and 43% with a SAPIEN (Edwards Lifesciences) valve. Most implanting centers performed <10 cases annually. One-third of transcatheter pulmonary valve implants were into homograft conduits, one-third were into bioprosthetic valves (BPVs), 25% were in native or patched right ventricular outflow tracts (RVOTs), and 6% were into Contegra (Medtronic Inc) conduits. Over the course of the study period, SAPIEN valve use grew from ∼25% to 60%, in large part because of implants in patients with a native/patched RVOT. Acute success was achieved in 95% of patients (95.7% in homografts, 96.2% in BPVs, 94.2% in native RVOTs, and 95.4% in Contegra conduits). Major adverse events occurred in 2.4% of procedures, more commonly in patients with a homograft (2.9%) or native RVOT (3.4%) than a prior BPV (1.4%; P = 0.004). CONCLUSIONS: This study describes novel population data on the use and procedural outcomes of TPVR with balloon-expandable valves. Over time, there has been increasing use of TPVR to treat regurgitant native RVOT anatomy, with the SAPIEN valve more commonly used for this application.


Assuntos
Próteses Valvulares Cardíacas , Valva Pulmonar , Substituição da Valva Aórtica Transcateter , Adulto , Humanos , Criança , Adulto Jovem , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Resultado do Tratamento , Sistema de Registros
9.
JACC Case Rep ; 26: 102058, 2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-38094173

RESUMO

The removal of balloon fragments from the pulmonary artery without damaging the pulmonary and tricuspid valves can be difficult. Four cases during transcatheter pulmonary valve replacement are described in which a novel retrieval system was used to facilitate safe removal. (Level of Difficulty: Advanced.).

10.
Biomark Res ; 11(1): 97, 2023 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-37957758

RESUMO

Congenital heart disease (CHD) represents a significant contributor to both morbidity and mortality in neonates and children. There's currently no analogous dried blood spot (DBS) screening for CHD immediately after birth. This study was set to assess the feasibility of using DBS to identify reliable metabolite biomarkers with clinical relevance, with the aim to screen and classify CHD utilizing the DBS. We assembled a cohort of DBS datasets from the California Department of Public Health (CDPH) Biobank, encompassing both normal controls and three pre-defined CHD categories. A DBS-based quantitative metabolomics method was developed using liquid chromatography with tandem mass spectrometry (LC-MS/MS). We conducted a correlation analysis comparing the absolute quantitated metabolite concentration in DBS against the CDPH NBS records to verify the reliability of metabolic profiling. For hydrophilic and hydrophobic metabolites, we executed significant pathway and metabolite analyses respectively. Logistic and LightGBM models were established to aid in CHD discrimination and classification. Consistent and reliable quantification of metabolites were demonstrated in DBS samples stored for up to 15 years. We discerned dysregulated metabolic pathways in CHD patients, including deviations in lipid and energy metabolism, as well as oxidative stress pathways. Furthermore, we identified three metabolites and twelve metabolites as potential biomarkers for CHD assessment and subtypes classifying. This study is the first to confirm the feasibility of validating metabolite profiling results using long-term stored DBS samples. Our findings highlight the potential clinical applications of our DBS-based methods for CHD screening and subtype classification.

12.
Front Mol Biosci ; 10: 1257079, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38028545

RESUMO

Background: Due to the poor prognosis and rising occurrence, there is a crucial need to improve the diagnosis of Primary Central Nervous System Lymphoma (PCNSL), which is a rare type of non-Hodgkin's lymphoma. This study utilized targeted metabolomics of cerebrospinal fluid (CSF) to identify biomarker panels for the improved diagnosis or differential diagnosis of primary central nervous system lymphoma (PCNSL). Methods: In this study, a cohort of 68 individuals, including patients with primary central nervous system lymphoma (PCNSL), non-malignant disease controls, and patients with other brain tumors, was recruited. Their cerebrospinal fluid samples were analyzed using the Ultra-high performance liquid chromatography - tandem mass spectrometer (UHPLC-MS/MS) technique for targeted metabolomics analysis. Multivariate statistical analysis and logistic regression modeling were employed to identify biomarkers for both diagnosis (Dx) and differential diagnosis (Diff) purposes. The Dx and Diff models were further validated using a separate cohort of 34 subjects through logistic regression modeling. Results: A targeted analysis of 45 metabolites was conducted using UHPLC-MS/MS on cerebrospinal fluid (CSF) samples from a cohort of 68 individuals, including PCNSL patients, non-malignant disease controls, and patients with other brain tumors. Five metabolic features were identified as biomarkers for PCNSL diagnosis, while nine metabolic features were found to be biomarkers for differential diagnosis. Logistic regression modeling was employed to validate the Dx and Diff models using an independent cohort of 34 subjects. The logistic model demonstrated excellent performance, with an AUC of 0.83 for PCNSL vs. non-malignant disease controls and 0.86 for PCNSL vs. other brain tumor patients. Conclusion: Our study has successfully developed two logistic regression models utilizing metabolic markers in cerebrospinal fluid (CSF) for the diagnosis and differential diagnosis of PCNSL. These models provide valuable insights and hold promise for the future development of a non-invasive and reliable diagnostic tool for PCNSL.

13.
Catheter Cardiovasc Interv ; 102(6): 1078-1087, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37925624

RESUMO

BACKGROUND: The Harmony TPV25 transcatheter pulmonary valve (Medtronic Inc.) is constructed with a self-expanding stent frame comprising six zigged nitinol wires sewn together and covered with knitted polyester fabric, with flared inflow and outflow ends and a porcine pericardial valve sutured to the central portion of the device. It was approved for treatment of pulmonary regurgitation after prior right ventricular outflow tract repair in 2021. Early outcomes of this procedure have been excellent, but little is known about valve durability or ultimate mechanisms of dysfunction. METHODS: We collected data on patients who underwent reintervention for TPV25 dysfunction and described findings related to distortion of the stent frame and tissue accumulation. RESULTS: We describe six patients who underwent valve-in-valve implant for TPV25 obstruction (peak catheterization gradient peak 28-73 mmHg) 10-28 months after implant. In all cases, there was tissue accumulation within the inflow and valve-housing segments of the device and deformation of the self-expanding valve frame characterized by variable circumferential narrowing at the junction between the valve housing and the inflow and outflow portions of the device, with additional geometric changes in all segments. All six patients underwent valve-in-valve implant that results in a final peak gradient ≤10 mmHg and no regurgitation. DISCUSSION: The occurrence of short-term Harmony TPV25 dysfunction in multiple patients with a similar appearance of frame distortion and tissue accumulation within the inflow and valve housing portions of the device suggests that this may be an important failure mechanism for this valve. Potential causes of the observed findings are discussed. It is possible to treat this mechanism of TPV25 dysfunction with valve-in-valve implant using balloon expandable transcatheter valves.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Obstrução da Via de Saída Ventricular Direita , Obstrução do Fluxo Ventricular Externo , Humanos , Suínos , Animais , Próteses Valvulares Cardíacas/efeitos adversos , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/cirurgia , Resultado do Tratamento , Cateterismo Cardíaco , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/cirurgia , Stents/efeitos adversos , Desenho de Prótese
14.
Ann Thorac Surg ; 116(5): 871-907, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37777933

RESUMO

Care and outcomes for the more than 40,000 patients undergoing pediatric and congenital heart surgery in the United States annually are known to vary widely. While consensus recommendations have been published across numerous fields as one mechanism to promote a high level of care delivery across centers, it has been more than two decades since the last pediatric heart surgery recommendations were published in the United States. More recent guidance is lacking, and collaborative efforts involving the many disciplines engaged in caring for these children have not been undertaken to date. The present initiative brings together professional societies spanning numerous care domains and congenital cardiac surgeons, pediatric cardiologists, nursing, and other healthcare professionals from diverse programs around the country to develop consensus recommendations for United States centers. The focus of this initial work is on pediatric heart surgery, and it is recommended that future efforts focus in detail on the adult congenital population. We describe the background, rationale, and methodology related to this collaborative effort, and recommendations put forth for Essential Care Centers (essential services necessary for any program), and Comprehensive Care Centers (services to optimize comprehensive and high-complexity care), encompassing structure, process, and outcome metrics across 14 domains.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cardiopatias Congênitas , Adulto , Humanos , Criança , Estados Unidos , Cardiopatias Congênitas/cirurgia , Cardiopatias Congênitas/etiologia , Procedimentos Cirúrgicos Cardíacos/métodos , Atenção à Saúde
15.
J Thorac Cardiovasc Surg ; 166(6): 1782-1820, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37777958

RESUMO

Care and outcomes for the more than 40,000 patients undergoing pediatric and congenital heart surgery in the United States annually are known to vary widely. While consensus recommendations have been published across numerous fields as one mechanism to promote a high level of care delivery across centers, it has been more than two decades since the last pediatric heart surgery recommendations were published in the United States. More recent guidance is lacking, and collaborative efforts involving the many disciplines engaged in caring for these children have not been undertaken to date. The present initiative brings together professional societies spanning numerous care domains and congenital cardiac surgeons, pediatric cardiologists, nursing, and other healthcare professionals from diverse programs around the country to develop consensus recommendations for United States centers. The focus of this initial work is on pediatric heart surgery, and it is recommended that future efforts focus in detail on the adult congenital population. We describe the background, rationale, and methodology related to this collaborative effort, and recommendations put forth for Essential Care Centers (essential services necessary for any program), and Comprehensive Care Centers (services to optimize comprehensive and high-complexity care), encompassing structure, process, and outcome metrics across 14 domains.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cardiopatias Congênitas , Adulto , Humanos , Criança , Estados Unidos , Cardiopatias Congênitas/cirurgia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Atenção à Saúde , Consenso
16.
BMC Cancer ; 23(1): 844, 2023 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-37684587

RESUMO

MOTIVATION: Ovarian cancer (OC) is a highly lethal gynecological malignancy. Extensive research has shown that OC cells undergo significant metabolic alterations during tumorigenesis. In this study, we aim to leverage these metabolic changes as potential biomarkers for assessing ovarian cancer. METHODS: A functional module-based approach was utilized to identify key gene expression pathways that distinguish different stages of ovarian cancer (OC) within a tissue biopsy cohort. This cohort consisted of control samples (n = 79), stage I/II samples (n = 280), and stage III/IV samples (n = 1016). To further explore these altered molecular pathways, minimal spanning tree (MST) analysis was applied, leading to the formulation of metabolic biomarker hypotheses for OC liquid biopsy. To validate, a multiple reaction monitoring (MRM) based quantitative LCMS/MS method was developed. This method allowed for the precise quantification of targeted metabolite biomarkers using an OC blood cohort comprising control samples (n = 464), benign samples (n = 3), and OC samples (n = 13). RESULTS: Eleven functional modules were identified as significant differentiators (false discovery rate, FDR < 0.05) between normal and early-stage, or early-stage and late-stage ovarian cancer (OC) tumor tissues. MST analysis revealed that the metabolic L-arginine/nitric oxide (L-ARG/NO) pathway was reprogrammed, and the modules related to "DNA replication" and "DNA repair and recombination" served as anchor modules connecting the other nine modules. Based on this analysis, symmetric dimethylarginine (SDMA) and arginine were proposed as potential liquid biopsy biomarkers for OC assessment. Our quantitative LCMS/MS analysis on our OC blood cohort provided direct evidence supporting the use of the SDMA-to-arginine ratio as a liquid biopsy panel to distinguish between normal and OC samples, with an area under the ROC curve (AUC) of 98.3%. CONCLUSION: Our comprehensive analysis of tissue genomics and blood quantitative LC/MSMS metabolic data shed light on the metabolic reprogramming underlying OC pathophysiology. These findings offer new insights into the potential diagnostic utility of the SDMA-to-arginine ratio for OC assessment. Further validation studies using adequately powered OC cohorts are warranted to fully establish the clinical effectiveness of this diagnostic test.


Assuntos
Óxido Nítrico , Neoplasias Ovarianas , Humanos , Feminino , Neoplasias Ovarianas/genética , Biópsia , Área Sob a Curva , Arginina
17.
J Am Coll Cardiol ; 82(12): 1206-1222, 2023 09 19.
Artigo em Inglês | MEDLINE | ID: mdl-37704311

RESUMO

BACKGROUND: We have followed a consistent, albeit evolving, strategy for the management of patients with pulmonary atresia or severe stenosis and major aortopulmonary collateral arteries (MAPCAs) that aims to achieve complete repair with low right ventricular pressure by completely incorporating blood supply and relieving stenoses to all lung segments. OBJECTIVES: The purpose of this study was to characterize our 20-year institutional experience managing patients with MAPCAs. METHODS: We reviewed all patients who underwent surgery for MAPCAs and biventricular heart disease from November 2001 through December 2021. RESULTS: During the study period, 780 unique patients underwent surgery. The number of new patients undergoing surgery annually was relatively steady during the first 15 years, then increased substantially thereafter. Surgery before referral had been performed in almost 40% of patients, more often in our recent experience than earlier. Complete repair was achieved in 704 patients (90%), 521 (67%) during the first surgery at our center, with a median right ventricular to aortic pressure ratio of 0.34 (25th, 75th percentiles: 0.28, 0.40). The cumulative incidence of mortality was 15% (95% CI: 12%-19%) at 10 years, with no difference according to era of surgery (P = 0.53). On multivariable Cox regression, Alagille syndrome (HR: 2.8; 95% CI: 1.4-5.7; P = 0.004), preoperative respiratory support (HR: 2.0; 95% CI: 1.2-3.3; P = 0.008), and palliative first surgery at our center (HR: 3.5; 95% CI: 2.3-5.4; P < 0.001) were associated with higher risk of death. CONCLUSIONS: In a growing pulmonary artery reconstruction program, with increasing volumes and an expanding population of patients who underwent prior surgery, outcomes of patients with pulmonary atresia or stenosis and MAPCAs have continued to improve.


Assuntos
Cardiopatias Congênitas , Atresia Pulmonar , Humanos , Aorta , Constrição Patológica , Artéria Pulmonar/cirurgia , Atresia Pulmonar/cirurgia
19.
medRxiv ; 2023 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-37732242

RESUMO

Purpose: Blood pressure gradient (ΔP) across an aortic coarctation (CoA) is an important measurement to diagnose CoA severity and gauge treatment efficacy. Invasive cardiac catheterization is currently the gold-standard method for measuring blood pressure. The objective of this study was to evaluate the accuracy of ΔP estimates derived non-invasively using patient-specific 0D and 3D deformable wall simulations. Methods: Medical imaging and routine clinical measurements were used to create patient-specific models of patients with CoA (N=17). 0D simulations were performed first and used to tune boundary conditions and initialize 3D simulations. ΔP across the CoA estimated using both 0D and 3D simulations were compared to invasive catheter-based pressure measurements for validation. Results: The 0D simulations were extremely efficient (~15 secs computation time) compared to 3D simulations (~30 hrs computation time on a cluster). However, the 0D ΔP estimates, unsurprisingly, had larger mean errors when compared to catheterization than 3D estimates (12.1 ± 9.9 mmHg vs 5.3 ± 5.4 mmHg). In particular, the 0D model performance degraded in cases where the CoA was adjacent to a bifurcation. The 0D model classified patients with severe CoA requiring intervention (defined as ΔP≥20 mmHg) with 76% accuracy and 3D simulations improved this to 88%. Conclusion: Overall, a combined approach, using 0D models to efficiently tune and launch 3D models, offers the best combination of speed and accuracy for non-invasive classification of CoA severity.

20.
World J Pediatr Congenit Heart Surg ; 14(5): 642-679, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37737602

RESUMO

Care and outcomes for the more than 40,000 patients undergoing pediatric and congenital heart surgery in the United States annually are known to vary widely. While consensus recommendations have been published across numerous fields as one mechanism to promote a high level of care delivery across centers, it has been more than two decades since the last pediatric heart surgery recommendations were published in the United States. More recent guidance is lacking, and collaborative efforts involving the many disciplines engaged in caring for these children have not been undertaken to date. The present initiative brings together professional societies spanning numerous care domains and congenital cardiac surgeons, pediatric cardiologists, nursing, and other healthcare professionals from diverse programs around the country to develop consensus recommendations for United States centers. The focus of this initial work is on pediatric heart surgery, and it is recommended that future efforts focus in detail on the adult congenital population. We describe the background, rationale, and methodology related to this collaborative effort, and recommendations put forth for Essential Care Centers (essential services necessary for any program), and Comprehensive Care Centers (services to optimize comprehensive and high-complexity care), encompassing structure, process, and outcome metrics across 14 domains.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cirurgiões , Adulto , Humanos , Criança , Coração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...